USER MANUAL ENGLISH13CAUTION!Rotate the speed adjusting knob (41 as Figure 2) to the minimum speed before depressingaccelerate pedal (26 as Figure 1) to avoid the machine running too quickly when it is started.Make sure the brush/pad is installed correctly before machine operating.SQUEEGEE INSTALLATION AND ADJUSTMENT1. Turn the ignition key (24 as Figure 1) to “I”, press One-Start button (38 as Figure 2), the squeegee (12 as Figure 1)is lowered down to the floor automatically.2. Unscrew two of adjusting knobs (21 as Figure 1) on the squeegee, then install the squeegee to the squeegeebracket and tighten the adjusting knobs. After that, connect the vacuum hose (20 as Figure 1) to the squeegee tocomplete the squeegee installation.3. Adjust the squeegee by squeegee adjusting handle (A, Figure 9).a) If there is gap between the ground and middle section of rearsqueegee blade (B), adjust the knob (A) in counterclockwisedirection (F) until all section of rear blade good touches withthe ground, the front blade touch the ground slightly.b) If there is gap between the ground and both end section ofrear squeegee blade (C and D), adjust the knob (A) inclockwise direction (E) until all section of rear squeegee bladegood touch with the ground, the front blade touch the groundslightly.SOLUTION TANK FILLINGNOTEIf the machine is equipped with ChemicalMixing System (optional) the tank mustbe filled with clean water, otherwise thetank can be filled with solution.1. Turn over the seat (A, Figure 10).2. (For machines without Chemical Mixing System)Use the front filler neck (B Figure 10) and the rearfiller neck (C Figure 10) to fill the tank (D Figure 10)with a solution suitable for the work to be performed.Refill to the reference mark “F” of the level checkhose (C Figure 10). Always follow the dilution in-structions on the label of the chemical product usedto prepare the solution. The solution temperaturemust not exceed + 104°F (+40°C).WARNING!Use only low-foam and non-flammabledetergents, intended for automaticscrubber applications.3. (For machines with Chemical Mixing System) Fill the tank (D Figure 10) with clean water by using the fillerneck (B Figure 10) and the rear filler neck (C Figure 10). Refill to the reference mark “F” of the level checkhose (C Figure 10). The water temperature must not exceed + 104°F (+40°C).DETERGENT TANK FILLING (FOR MACHINES WITH CHEMICAL MIXING SYSTEM)1. Open the cover (G Figure 10) and check that the recovery tank (F Figure 10) is empty, otherwise empty it withthe drain hose (E Figure 10).EACFB DGFEDCBAHIFigure 10Figure 9