Nivetec Signet 515 Operating Instructions Manual
4 Signet 515/2536 Rotor-X Flow SensorsPVDFPolypropylene102030405060708090100110120130140150160170180190200210.71.42.12.83.44.14.85.56.26.97.68.39.09.710.311.011.712.413.113.814.5(bar)(psi)0-20 0 20 40 60 80 100°F°C-4 32 68 104 140 176 212102030405060708090100110120130140150160170180190200210.71.42.12.83.44.14.85.56.26.97.68.39.09.710.311.011.712.413.113.814.5(bar)(psi)0-20 0 20 40 60 80 100°F°C-4 32 68 104 140 176 212PVDF PolypropylenePVCSpecifi cationsGeneralFlow Rate Range:515 .................................... 0.3 to 6 m/s (1 to 20 ft/s)2536 .................................. 0.1 to 6 m/s (0.3 to 20 ft/s)Pipe Size Range ................... DN15 to DN900 (½ in. to 36 in.)PVC......................................DN15 to DN100 (½ in. to 4 in)Cable Length ........................ 7.6 m (25 ft) standard515 .................................... 60 m (200 ft) maximum2536 .................................. 305 m (1000 ft) maximumCable type ............................ 2-conductor twisted pair w/shield (22 AWG)Minimum Reynolds Number .. 4500Materials:Cap Material ......................... Glass Filled Polypropylene515: Red2536: Blue2536 (PVC): GrayWetted Materials:Sensor Body ......................... Glass Filled Polypropylene(black) PVDF, or (gray) PVCO-Rings ................................ FPM (Std), EPR (EPDM) orFFPM optionalPin ........................................ Titanium, Hastelloy-C or PVDF;optional Ceramic,Tantalum, or Stainless SteelRotor ..................................... Black PVDF or Natural PVDF;optional ETFE with or withoutcarbon fiber reinforced PTFEsleeve for rotor pinShipping Weight:-X0 .................................... 0.454 kg (1 lb)-X1 .................................... 0.476 kg (1.04 lbs)-X2 .................................... 0.680 kg (1.50 lbs)-X3 .................................... 0.794 kg (1.75 lbs)-X4 .................................... 0.850 kg (1.87 lbs)-X5 .................................... 1.0 kg (2.20 lbs)3519 .................................. 1.3 kg (2.86 lbs)PerformanceLinearity ................................ ±1% of maximum range@ 25 °C (77 °F)Repeatability ......................... ±0.5% maximum range@ 25 °C (77 °F)Electrical515 SensorFrequency............................. 19.7 Hz per m/s nominal(6 Hz per ft/s)Amplitude.............................. 3.3 V p/p per m/s nominal(1V p/p per ft/s)Source Impedance ............... 8 kΩ2536 SensorFrequency............................. 49 Hz per m/s nominal(15 Hz per ft/s nominal)Supply Voltage...................... 5 to 24 VDC ±10% regulatedSupply Current...................... <1.5 mA @ 3.3 to 6 VDC<20 mA @ 6 to 24 VDCOutput Type .......................... Open collector, sinkingOutput Current ...................... 10 mA maximumEnvironmental RequirementsPressure/Temperature RatingsStandard and Integral Sensors:Polypropylene Body:• 515: 1.7 bar (25 psi) max @ 90 °C (194 °F)12.5 bar (180 psi) max @ 20 °C (68 °F)• 2536: 1.7 bar (25 psi) max @ 85 °C (185 °F)12.5 bar (180 psi) max @ 20 °C (68 °F)Operating Temperature......... -18 °C to 66 °C (0 °F to 150 °F)PVDF Body :• 515: 1.7 bar (25 psi) max @ 100°C (212 °F)14 bar (200 psi) max @ 20 °C (68 °F)• 2536: 1.7 bar (25 psi) max @ 85 °C (185 °F)14 bar (200 psi) max @ 20 °C (68 °F)Operating Temperature......... -18 °C to 100 °C (0 °F to 212 °F)PVC Body:• 2536: 6.9 bar (100 psi) max @ 60 °C (140 °F)14 bar (200 psi) max @ 20 °C (68 °F)Operating Temperature......... 0 °C to 50 °C (32 °F to 122°F)Polypropylene Wet-Tap Sensor Body:• 7 bar (100 psi) @ 20 °C (68 °F) max• Max Removal Rating......... 1.7 bar @ 22 °C (25 psi @ 72 °F)Operating Temperature......... -18 °C to 66 °C (0 °F to 150 °F)515 (8510) Sensor 2536 (8512) SensorStandards and Approvals• RoHS CompliantChina RoHS (Go to www.gfsignet.com for details)• Manufactured under ISO 9001 for Quality,ISO 14001 for Environmental Management andOHSAS 18001 for Occupational Health and Safety.P51530• NSF (P51530-PX versions only)• Lloyd's Register Type Approval2536• NSF (3-2536-PX versions only)• CEDeclaration of Conformity according to FCC Part 15This device complies with Part 15 of the FCC rules.Operation is subject to the following two conditions:(1) This device may not cause harmful interference, and(2) This device must accept any interference received,including interference that may cause undesired operation. |
Related manuals for Nivetec Signet 2536
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine