183. Connect cable C04 to the free AMPconnector at the center of the sprayer onthe Hagie wiring.4. Connect cable C05 to one of the freeends of cable C04 and route it to thechassis roll sensor, which is mountednear the cab.5. Connect one of the remaining AMPconnectors on cable C04 to the main liftsensor and the final AMP connectormust connect to the boom frame rollsensor.6. Cable-tie installed cables every 12inches.IMPORTANT:Provide enough slack in all cables toaccount for the movement of the mainsection, parallel lift, and FOLDING boommovement.4.6 COMPLETING THE INSTALLATION1. Start up your sprayer and test thesprayer’s functionality. The NORACControl Panel does not need to bepowered up for the original switches tofunction. Unfold the booms andraise/lower each boom and main section.Again confirm that thecabling/hoses are agreeable to theentire range of motion.2. If any functions do not work, review thehydraulic and electrical portions of thismanual to check for proper installation.If you still have trouble, contactNORAC for assistance.3. Turn on the power for the UC4+ ControlPanel using the switch on the side of itschassis. .4. The procedure for the installation of theUC4+ Spray Height Control system isnow complete. Begin the AUTOMATICSYSTEM SETUP procedure asdescribed in the UC4+ Spray HeightControl Operator’s Manual (M01).