www.norcold.com/cda 23N611v, N811v ModelsRefrigerator Service ManualLP Gas System - cont’d.Gas LockoutCODE 0CONSTANT RED INDICATOR LIGHTRefer page 13 for additional details.Solid Red Indicator LightFor safety reasons, the refrigerator’s electronic controls aredesigned so the ignition trial (maximum amount of time the gasvalve and igniter can be left on) is limited to 30-seconds whenoperating in the LP GAS mode. Certain conditions can causeair in the gas supply line which may result in a gas lockoutcondition.Conditions That Cause Air in Gas Supply Lines• When starting the refrigerator for the first time• After storage• After replacing the propane gas tankResults of Air in Gas Supply Lines:• Gas valve and igniter outputs will be turned off• LP Gas mode will be “locked out”• Power ON indicator is SOLID REDReset a Gas Lockout Condition - All ModelsTo reset a gas lockout condition, power the refrigerator Offand back ON. The amount of air in the LP gas supply linesdetermines if the procedure needs to be repeated severaltimes.1. Open lower intake vent at refrigerator rear.2. Remove both white wires from gas valve solenoid3. Insert volt ohm meter leads into white wires and setmeter to read DC volts.4. Unplug AC cord from unit to select LP Mode.5. Verify meter reads approximately 12 volts DC andigniter sparks at burner6. After approximately 30 seconds, 12 volt outputmeasured at white wires is 0 volts and sparking atburner will stop. This means the gas valve safety circuitis operating correctly. The appropriate error will displayon the optical display7. Reconnect white wires to the gas valve solenoid (itdoesn't matter what wire is attached to what terminal)8. Close lower intake vent.Gas Safety Valve Test