Repair8-10Part 1602966−05 2015 Nordson CorporationLift Cylinder Installation1. Remove the lift cylinder packaging and inspect it for damage.2. See Figure 8-7. Install the trunnion flange on the new cylinder.3. Thread the locknut on the new cylinder rod, then thread the clevis all theway onto the new cylinder rod and lock it in place with the locknut.4. Unsnap the clevis pin clip from the clevis and remove the pin.5. Remove the four M8 x 75 screws from the bottom of each side of thebearing block and lift off the bearing caps.6. Remove the bearings from the bearing caps. Install the bearings on thecylinder trunnions, with the bearing flanges toward the cylinder.7. Install the cylinder through the square opening in the roof of the feedcenter, then carefully guide the bearings into the trunnion support block.8. Install the bearing caps on top of the bearings, noting that the bearingcaps have position letters stamped on each cap which match lettersstamped on the block. Reinstall with the matching letters aligned.Secure the caps to the support block with the four M8 x 75 screws.9. Connect air tubing to the cylinder: 6-mm tubing from Down regulator to upper flow control valve. 6-mm tubing from Up regulator to lower flow control valve. 6-mm tubing from solenoid #3 SOL326 to the cylinder lock.10. Rotate the E-Stop button on the feed center control panel clockwise torelease it and turn on feed center power and air.11. Lower the cylinder clevis down the the lance carriage, which should beresting on the stop bolt at the bottom of the V-track rail.12. Connect the clevis to the lance carriage with the clevis pin. Snap the pinclip around the clevis.13. Install the proximity switches on the cylinder at the same positions as onthe old cylinder: LS306: Hopper position LS307: Box position LS308: Purge position14. Adjust the position of the purge proximity sensor (LS308).a. Slide the switch up or down until it senses the magnet in the cylinderpiston and the LED lights.b. Note the position where the LED turned on, then continue sliding it inthe same direction until the LED turns off.c. Slide the switch back up and position it in the midpoint between theoff positions and secure it in place.NOTE: Refer to Lift Cylinder Proximity Switch Adjustment in the Installationsection of this manual (page 3-11) to set the positions of the Box switch(LS307) and the Hopper switch (LS306).15. Raise and lower the lance assembly and adjust the cylinder flow controlvalves for 6 seconds full travel in each direction.