System Setup 2-9Part 1612500−02 2018 Nordson CorporationTo provide air to your system, an input air kit with connectors, couplings,and 10-mm air tubing (15-ft for dolly systems, 25-ft for rail mount systems)is available.Refer to the Parts section for filter kits, replacement elements, and input airkit part numbers and ordering information.Mobile SystemsConnect 10-mm air tubing from your compressed air supply to the air inputfitting on the rear panel of the dolly.Rail Mount SystemsSee Figure 3-9.1. Use the mounting bracket (4) as a template to mark and drill mountingholes in the selected mounting surface. Make sure there is sufficientclearance to connect air tubing and change the filter element.2. Install the two male connectors (2) included in the kit in the filter inputand output ports.3. Install the mounting bracket on the filter, using the included M5 screws(3), on the side of the filter opposite the release latch (6).4. Mount the filter with customer-supplied fasteners (7).5. Note the orientation of the flow indicator (5) on the top of the filter. Cut10-mm blue air tubing to the required lengths to connect the air supplyto the filter and the filter to the controller, then connect the tubing.112234657FROM SUPPLYTO CONTROLLERFigure 2-9 Air Filter Installation − Wall and Rail Mount Systems1. 10-mm air tubing (blue)2. 10-mm tube x 1/2 male connectors3. M5 screws4. Bracket5. Flow indicator6. Release latch7. Customer-supplied fasteners