Maintenance 5‐12013 Nordson CorporationAll rights reserved MicroMaxIssued 12/13P/N 768635_11Section 5MaintenanceWARNING: Allow only qualified personnel to perform thefollowing tasks. Observe and follow the safety instructions in thisdocument and all other related documentation.WARNING: Breathing in certain airborne dusts (includingfinishing powders) may be hazardous to health. Ask the powdermanufacturer for a Material Safety Data Sheet (MSDS) forinformation. Use appropriate respiratory protection. Visually check the complete system for leaks, rectify. Check the operation of any powder transfer systems. At Least every hour press the filter cleaning pulse button located onthe main control panel. Every four (4) hours, with the fan operating, clean the booth interiorwith a rubber squeegee, or other non‐sparking cleaning device, pullingthe powder into the hopper section of the booth. Every four (4) hours or less check the feeder hopper for powder level.Before adding powder use the vacuum cleaner to prevent powder dustfrom getting out into the room. Every four (4) hours check the powder pump and gun, clean accordingto the product manual. Every four (4) hours clean U.V. detector lenses if fitted. Every four (4) hours run the cartridge cleaning sequencer for at leastten (10) minutes, longer if necessary, to maintain air flow.1. Daily Maintenance