SDS Meters6Part 1009912E 2005 Nordson CorporationInstallationWARNINGAllow only qualified personnel to perform thefollowing tasks. Follow the safety instructions in thisdocument and all other related documentation.1. Find a suitable location near your workstation. Theshop floor at the installation site should be clean andlevel. See Figure 3 for dimensions.2. Connect a minimum of 60 psi (4.14 bar) of cleanshop air to a filter regulator input.3. See Figure 4. Use customer-supplied bolts andwashers to mount the the SDS meter. M10 x 4mounting holes (4) are provided.4. The metering cylinder can be rotated in 90-degreeincrements by removing the screws (3) securing thehydraulic section to the drive train (2). Tighten thescrews to 82 ft-lb (111 N•m) when securing themetering cylinder to the drive train.5. Connect the following: water circulation lines from the temperaturecontrol unit to the fittings (9) material hose to the material inlet fitting (7) pressure transducer cable to the pressuretransducer (5) servo connectors (1) to a J-box orextension cables air lines from the pneumatic manifold tothe fittings (8) Heated Versions—cable from the controller tothe cordset (10)10476895132Figure 4 Typical Installation