CRC200R USER GUIDE ISSUE 025-11T i m e z o n e 2 - 0T M i n : x xEnter a 2-digit number for the ‘To Minute’ of the first active periodin Time Zone 2 and press .T i m e z o n e 2 - 0M o n : N OUse the key to toggle between ‘’yes’ and ‘no’, then press .When set to ‘yes’, the active period set above will be active onthat day of the week (Monday in this case).Repeat this sequence for each day of the week. Ignore ‘Hol’(holiday) as this is not supported in the current build.T i m e z o n e 2 - 1F H o u r : x xRepeat the above procedure for the second active period of TimeZone 2. On completion, you will then be given the same set ofparameter options for Time Zone 3:T i m e z o n e 3 - 0F H o u r : x x Repeat the procedure for Time Zone 3.Upon completion of all Time Zone parameters, the unit will move to the next sub-menu item.5.5.5 Card FormatThis sub-menu item is used to set the format of the card data that will be read to the CRC200R sothat it can identify the card number to check. Please refer to Appendix B for help on identifying therequired data.This sub-menu item is automatically selected when the final parameter of ‘Timezones’ (or ‘DoorOpen TZ’) has been entered.To reach this sub-menu item from the initial display, press once and then press repeatedlyuntil the ‘Installer’ screen is displayed, press once again to enter the sub-menu, and pressrepeatedly until the following screen is displayed:C a r d F o r m a tPress and carry out one the following two procedures according to the card format.Display ActionC a r d F o r m a tM a gThe CRC200R supports:Mag - Clock & Data (ISO/ABA Track 2) displayed asWiegand - Wiegand format (variable)W26 – Standard 26 bit Wiegand.Use the key to select the required format and then press .The next set of parameters depend on the chosen format (nofurther parameters are required for W26).