Page 60 of 162 Software maintenance tools553-3041-500 Standard 1.00 September 2004which can require some corrective action. System events with a severity ofInfo are for informational purposes only and are not considered alarms.Alarm NotificationThe Alarm Notification application receives SNMP events from designatednetwork equipment over an Ethernet network and sends out alarmnotifications when specified event conditions are detected. Received eventsare compared to a set of rules which can activate notifications of differenttypes. These notifications include:• SNMP traps or events transmitted to predefined destinations• text notification over a modem• pager notification to alpha or numeric pagers• e-mail using Simple Mail Transfer Protocol (SMTP)• logFor detailed information on Alarm Management, see Optivity TelephonyManager: System Administration (553-3001-330) and Simple NetworkManagement Protocol: Description and Maintenance (553-3001-519).Interactive diagnosticsLoad non-resident software programs into the memory through the OTMSystem Terminal or an SDI terminal. These programs, also called overlays orloads, are identified by a title and a number which is preceded by themnemonic for load (for example, Trunk Diagnostic — LD 36).The programs used in Midnight and Background Routines are also usedmanually as interactive diagnostic programs. See Table 9 on page 57.Non-resident programs are used interactively with a command and responseformat. In this format, enter a command that tells the system to perform aspecific task. The system then performs the task and sends system messagesindicating status or errors back to the user.