Clearing faults Page 75 of 162Communication Server 1000E MaintenanceClearing Signaling Server faultsThe Signaling Server is a commercial one-use server that provides signalingfor the CS 1000E system. It has ELAN and TLAN network interfaces, whichare connected to an Ethernet switch through CAT 5 cables. It has two serialports and visual indicators for maintenance. It has three push buttons, oneeach for power, reset, and INI (initialization). The INI button, USB ports,keyboard port, and mouse port are not supported.Table 13Signaling Server Diagnosis (Part 1 of 2)Condition Possible Cause ActionSignaling Server notrunning. All LEDs off.No power to systemPower supply failedCheck power cableReplace Signaling ServerSignaling Server runningwith no fan noiseFan failed Replace Signaling ServerFloppy drive tries accessingfloppy but failsFloppy media is corruptedFloppy not formattedReplace floppyFormat floppyFloppy drive not accessingfloppy & green light notilluminating.Floppy drive failed Replace Signaling ServerCD-ROM drive tries toaccess CD-ROM but stopsCD-ROM media is corrupted Replace CD-ROM diskCD-ROM drive notaccessing CD-ROM. Nogreen light.CD-ROM Drive failed Replace Signaling Server100BT light not on Auto Negotiate Failed Provision Ethernet Switch to100MB. Switch Auto Negotiateoff.