107Using Passport 4400 Install Tool Version 4.2No Response from theNext ButtonPassport 4400 Fails Following a ResetUnable To Add Multiple IP AddressesError Condition: In Wizard mode, you click on Next, but nothing happens.Possible cause: You did not enter valid data into a required field.Possible resolution (1): Enter required data (unless you want to skip the port).Possible resolution (2): Click on Next Port to skip this port and move on to the next.Error Message: “The system is NOT up”Possible cause: If you are connected to the unit through the Ethernet port,and you changed the IP address of that port, Install Tool willnot be able to reestablish the connection following the reset.Possible resolution: Exit from Install Tool, then reestablish the connection usingthe new IP address.Error Message: “Problem AddingIP Address(es)Possible cause: The IP Address that you specified is on the same segment asan address already configured for the port (each IP addressmust be on a different segment).Possible resolution: Verify that each IP address that you are adding is on adifferent segment.