Quick-Start Guide300855-C Rev. 00 5The Model 8000 console terminal is configured as follows:• 9600 baud• 8 data bits• No parity• 1 stop bit• XON/XOFF flow controlDetailed installation instructions are in the Nortel Networks 5399 Access SwitchHardware Installation Guide and Installing the Nortel Networks 8000 AccessSwitch.Task 4: RAC ConfigurationTo configure the RAC, it must be in ROM monitor mode. Press and hold the Resetbutton on the Model 8000. After the green stat light flashes, release the Resetbutton. After all the lights flash again, press the Reset button again. The orangelight should illuminate indicating the self-test sequence. The self-test completeswhen the alternating green %Utilization light illuminates. Lastly, the orange attnlight should illuminate. This indicates that the Annex is in ROM monitor mode,and the monitor:: prompt should display on the terminal connected to the consoleport.The Model 5399 is accessible through the Slot Selection Menu on the System5000 MSX console. To enter monitor mode on a Model 5399 RAC:1. Enter r <slot number> to reset the 5399.Do you want to reset the 5399 y/n [y]:y2. Enter c on the slot selection menu to connect and enter the 5399’sslotnumber.3. Press the space bar to enter monitor mode.After the RAC is in ROM monitor mode, perform the following tasks:• Set the network addresses• Set the operating image• Configure the interface sequence• Enable the allow_snmp_sets parameter