Installing and connecting a WSS 47Nortel WLAN—Security Switch 2300 Series Installation and Basic Configuration GuidePowering on a WSSPowering on a 2360/2361, or 2380To power on a 2360/2361, 2380 switch:1 Make sure any insertable power supply is fully seated in the WSS.2 For each power supply that you are using on the WSS, attach a power cord to an AC powersource.3 Plug each power cord into a WSS power supply.The WSS begins booting as soon as you plug in the power cord(s).4 Observe the power supply LED for each connected power supply to verify that the LED issteadily glowing green. This indicates normal power supply operation.5 On the 2380 switch only, wait a few seconds, then observe the Mgmt LED to verify that it isbreathing (repeatedly flashing bright green, then fading) to indicate that the WSS hassuccessfully booted and is operating normally.Warning! The WSS relies on the building’s installation for overcurrent protection.Ensure that a fuse or circuit breaker no larger than 120 VAC, 15 A U.S. (240 VAC, 10 Ainternational) is used on the phase conductors.Caution! If a 2350 or 2360/2361 is connected to Power Sourcing Equipment (PSE), itis possible for the switch to remain powered on even when the power cord is unplugged.PSE can be a dedicated PoE injector or even another networking switch such as the WSSthat is capable of supplying PoE. To completely power off a 2350 or 2360/2361, unplug thepower cord, then unplug all Ethernet cables that are connected to other PoE devices.Note. If the WSS has two power supplies, use a separate AC power source foreach supply to add redundancy. If one power source fails, the switch can continueto operate using the other power source.