NWB & NWB-HC IM28 OCT 2014 Page 21Instruction Manual NWB & NWB-HC IM 28 OCT 2014If you select the Dryer Status from theAdvanced Functions screen, all of the dryerparameters can be monitored. Reactivation inlet and outlettemperature Process inlet and outlet temperature System dew point Calculated desiccant wheel RPHThe graphics on this screen will changeappearance in accordance with the mode ofoperation.Intelligent Regen is an energy-saving featurethat is activated at the factory prior toshipment. See below.INTELLIGENT REGEN - NO ENTRY REQUIREDShipped Configured and EnabledIntelligent Regen constantly monitors the regeneration inlet and outlet temperatures and controlsthem to optimize the energy and dew point performance of the dryer. The control will lower (or raise)the regeneration inlet temperature by 5 F. (2.4 C) each time the desiccant wheel rotates to ensurethat adequate, but not excess heat, is used to maintain the dryer dew point performance whileinsuring that no excess heat is used and wasted. Once the dryer has optimized itself, changescease. The system insures the best dryer performance despite the materials processed, theirmoisture level or any changes in dryer processing rate thereby saving energy and improvingperformance.11.2 Dryer Alarms (Level 3)11.3 Dryer Status (Widely Used By processors)Alarm settings are pre-set at NOVATECbut Level 3 personnel can re-set them.