1IMPORTANT SAFETY INSTRUCTIONSWARNING – TO REDUCE THE RISK OF FIRE, ELECTRICSHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOW-ING:1. All electrical work must be done in accordance with local ornational electrical code as applicable. For safety, this productmust be grounded. If you are unfamiliar with methods of in-stalling electrical wiring, secure the services of a qualified elec-trician.2. When wiring, servicing or cleaning this unit, turn off power andlock out service panel. Failure to do so could allow others orthermostat to turn on power unexpectedly which may causefatal electrical shock.3. To avoid electrical shock:• Do not install unit in a tub or shower enclosure or any loca-tion where it may come in contact with water.• Never place a switch where it can be reached from a tub orshower.4. Do not install this unit in an area where chemicals and otherflammables are stored or used. Explosion and fire may result.CAUTION1. This product may ONLY be installed in a wall. Do not mount inany other position.2. Install heater at least 12" from floor or any adjacent verticalsurface.3. Do not locate heater behind a door, furniture, drapes, etc.,where the air flow to the unit would be restricted.4. Provide heater with an appropriately-rated electrical circuit toprevent tripped breakers or blown fuses.5. Do not connect heater to dimmer switch or speed control.6. To avoid motor bearing damage and noisy and/or unbalancedimpellers, keep drywall spray, construction dust, etc., off powerunit.7. Please read specification label on product for further informa-tion and requirement.INSTALLATION INSTRUCTIONSREAD & SAVE THESE INSTRUCTIONS!Wall HeaterMODELS: 9192NT, 9194NT, 9198NTFIGURE 1PLAN THE INSTALLATIONThis heater is intended to be used to supply supplemental heatfrom a wall location in new or existing construction.Choose a location where edge of heater will be at least 12" fromthe floor or any adjacent vertical surface.The heater can be operated using its built-in thermostat or a re-mote thermostat (Choose either the Model 86W Line-Voltage ther-mostat or use the Model 82 Transfomer/Relay with an appropriatelow-voltage thermostat.). The Model 85NT Kit is available for sur-face-mount applications. Purchase these accessories separately.Plan to supply the heater with proper line voltage and appropriatepower cable.NOTE: Power can be tapped from a nearby circuit depending onthe heater wattage required and the amperage rating of the circuit.Heater can be converted to half-wattage to avoid overloading suchcircuits.MODEL VOLTS AMPS WATTS BTU/HR9192NT 240 8.33/4.17 2000/1000 6827/34139194NT 240 12.50/6.25 3000/1500 10240/51209198NT 240 16.67/8.33 4000/2000 13653/6827DRYWALLTHERMALOVERLOADGRILLEBUILT-INTHERMOSTATHEATER HOUSINGPOWER CABLEBold ratings are factory wired.See “OPTIONAL WIRING CONVERSIONS” section for wattageconversion instructions.Refer to FIGURE 1Follow these basic steps when installing this heater:1) Nail housing to studs.2) Connect power cable.3) Fasten heater assembly and grille to housing.