SIMPLY PRECISE317.6 Mounting of the Scanning Head• Clean all mounting surfaces of the scanning head and machine element before mounting. Removethe protection foil from the scanning window of the scanning head.• Clean the scanning head surfaces carefully by using a soft and lint-free rag. Use a solvent ifnecessary (e.g. Acetone or Alcohol).• The mechanical mounting of the scanning head can be done in two ways:Mounting of a Scanning Head with Internal Screw Threads M2.5Mounting of a Scanning Head with Through-Holes Ø 2.2 mmImage 20Image 21