EN-22 CKW-55 CHECKWEIGHER3.5.3 Library OperationThe CKW-55 Indicator allows the storage of checkweighing data in 20 Library locations, designated ID 01 to ID 20. EachLibrary location includes: a Part Number or name, Pre-set Tare, Maximum, Minimum, and Target value. Data entered into thelibraries can be recalled for use, edited or deleted.The LIBRARYSave button can be locked to prevent unauthorized changes to the data (refer to Section 3.6.8 Lockout Menu).Summary of Library Key FunctionsUse the following buttons to establish checkweigh set point values (Checkweigh Mode and Library is on).LIBRARYSave Short Press1. Initiates the Library sequence, and2. Accepts the displayed values and advances to the next sequence.Long Press during part number display or while END is displayed loads the library data, and exits toactive weigh mode.NEXT +/- 1. During a Library ID display, short press advances to the next higher Library ID.2. Long press will begin scrolling through Lib ID’s more quickly.3. During Part Number entry, converts a 3 digit ASCII code to an alpha-numeric character.4. During numeric value entry sequence, short press toggles the displayed value between negative andpositive.C 1. Short press in numeric entry sequence, clears one digit at a time. A long Press during data entryerases all digits.2. While END is displayed, a long press will erase the data in the selected library.Exit Exits any Library function.Entering and Editing Library DataIn the Mode menu, Library should be On. Library data is viewed in the Set Point Input setting as it was entered. In thisexample, Set Point Input setting is Variance.Note: In Library entry mode, LIBRARYSave is used to confirm and advance to the next setting instead of TARGET button.....Press the LIBRARYSave button to display the last active Library ID.To choose another Library ID location, press the NEXT +/- button. The next Library ID locationflashes, then the corresponding Part Number.Display shows a flashing - - - - - - to indicate that there is no existing Part Number specifiedfor this Library ID location. For improved identification, an identifying part number or productID may be entered.Enter the desired Part Number (up to 6 digits + 6 decimal points) (example 30123.0) usingthe numeric keys.