43502101TH Rev.1 48 /Oki Data CONFIDENTIAL3.1.3 EEPROM Initial Setting Range for EventsAs for initialization of EEPROM, ranges differ the whole phenomenon."O" is initialized. "–" is not initialized.Table 3-1 The Initial-Setting domain of EEPROMUser Maintenance MenuEEPROM RESET OperationF/W Revision check error atthe time of a power on.CU EEPROM area mappingRevision check error at thetime of a power on.Brands area check error atthe time of a power on. (*1)Engine Maintenance MenuENGINE RESET OperationPU EEPROM area mappingcheck error at the time of apower on.System Maintenance MenuEEPROM RESET Operation1234567CU EEPROM Area PU EEPROM AreaNo Event FactoryDefaultAreaUserMenuAreaAdministrator Menu/System MaintenanceMenu Area (*3)Engine Maintenance Menu AreaBrandsAreaF/WRevisionArea DrumCounterPageCounterTonerDotCounterOPMenuArea(*1) The model (forcing) which operated before is for operating as another model (forcing), and a Brands check isrecognized as an error and resets change of the Brands point by the PJL command, operation at the time ofthe power supply injection by new EEPROM, etc.(*2) It restricts to the time when whose page counter is 500 or less sheets, and is reset by 0. (ENGINE RESET bythe PJL command is not this limitation.)(*3) Although a DOT SHIFT setting menu exists in a system maintenance menu, since setting value preservationarea is arranged at PU EEPROM AREA, even when the system maintenance menu item is initialized, a DOTSHIFT setup is not initialized. On the contrary, when PU EEPROM AREA is initialized, a DOT SHIFT setup isalso initialized.(*4) A DOT SHIFT setup is not initialized.