5.2.3.5 Sideways adjustmentProcedures:1) Set the specified test chart (Figure 5.4.19). adjust the document guide to the chartwidth, and place the chart at the reading position.2II Additional line(about 1 mm in thickness)!mni ti7Fig. 5.2.19 Additional line on the specified chart2) Use the CH2 channel of the oscilloscope to observe the marker signal at test-pointTPl on the MCNTZ PC board, and use the CHl channel for the sensor outputwaveform, at the side reading position with the alternation ALT mode of theoscilloscope.CH2 l-l (Marker signal)I (Sensor output)CHl$Right edge of B4 for one marker bit(Marker signal)* Detail Tsensor output for vertical line on the chart.I CHl (Sensor output!Fig. 5.2.20 Side position adjustment5 - 2 1