40496501TH Draft Version 88Item No.1ItemsProtector Gap Adjustment(1)Range Adjustment(2)Protector GapStandard Value Illustration Adjustment Method1Remove the Rear Cover (B), and setDip Switch 1 on the board to “ON”(maintenance mode).2Close the access cover, and turn onthe printer while pressing Switches 7and 10 on the operation panel. (Thisstarts the auto gap adjusting mode.)The platen moves forward/ backwardup to the adjusted position.3When the platen stops, turn off theprinter.1Insert the thickness gauge betweenthe platen and the protector frame toverify the protector gap value B is bet-ween 0.12 and 0.16 mm.Notes:Although the adjustment should use arange from 0.12 to 0.16mm, the configura-tion should use a range from 0.09 to 0.2mm2If adjustment is required, screw downthe ribbon guide post with the Philipsscrewdriver and adjust the protectorframe to make the protector gap valueB between 0.12 and 0.16 mm, then fixthe protector frame.Notes:a) The protector frame should bemounted parallel with the platen, whenmeasured at the right/left gap measur-ing points.DIP SwitchLower CoverRear Cover (B)ONOFF 1 2 3 4ONOFF 1 2 3 4DIP SWTemporaryMaintenancePARKTEARPATHONLINERESET GROUPPOWERALARMITEM OPTIONMENUSTORETOFSHIFTO N - L I N E E P SF R O N T F E E D CONFIGLFMicroFeedDownFF/LOADMicroFeedUp1 2 3 456789 0 A B C123Gap Measuring PointsRibbon Guide PostProtector FramePlatenBB