2KZ/2K01-3-57U161 Setting the fuser control temperatureDescriptionChanges the fuser control temperature and control temperature correction value and other setvalues.PurposeNormally no change is necessary. However, this mode can be used to prevent curling or creasingof paper, or solve a fuser problem on thick paper.Setting1. Press the start key.2. Select the item to be set.3. Change the setting value using the cursor left/right keys.4. Press the start key. The value is set.Item No. DescriptionDisplay Description SettingrangeInitialsettingCopyCurb(Edge)Prevention temperature of overtem-perature rise under copy100 to 250 210Curb(Edge) Prevention temperature of overtem-perature rise100 to 250 240Return(Edge) Return temperature of overtempera-ture rise100 to 250 190Ready(Edge) Ready display temperature 0 to 200 140Pressure(Press) Pressurizing beginning temperature 0 to 200 100Highspeed(Center)Full speed shift temperature 0 to 200 130Ready(Center) Ready display temperature 100 to 200 150Drive(Center) The second stability temperature 100 to 200 160Full speed(Cen-ter)Print control temperature 100 to 200 160Wait(Center) Control temperature when beingstanding by100 to 200 130WarmUpCurb(Center)Electric power control temperature atstart-up0 to 200 160Curb(Center) Prevention temperature of overtem-perature rise170 to 250 240Low power(Cen-ter)Low electric power controltemperature0 to 200 90Ready(Press) Ready display temperature 0 to 200 60Curb(Press) Prevention temperature of overtem-perature rise170 to 250 240Wait Off-set(Press)Correction temperature when beingstanding by0 to 200 100Y113010-4 Sevice Manual