Test Procedures27FAS Test ProcedureThe user will be prompted with the correct FAS test procedure.During each FAS test fully depress the accelerator quickly but not violently in underone second.Press the tick key to acknowledge and proceed.The display will show the smoke measurement and a 10 second count down.The user should now be seated in the drivers seat with a handset or the PC screen inviewing distance, and follow the automated instructions:A schedule of up to 6 accelerations is automatically progressed by the OmiSmokewith automatic calculation of pass / fail status. It may also request another repeatedacceleration if insufficient data was recorded.Fast Test (Category A only)After the 1st acceleration, on category A vehicles only, a reading of less than or equalto the fast pass smoke limit (currently 1.5 K (m-1 )) will automatically produce a fastpass and as such will terminate the schedule at this point with a pass status. The testresults and print out will state ‘Fast Pass Result’.For all other conditions the schedule will continue prompting the user to accelerateand release until the arithmetic mean of the latest 3 readings is within the pass limit.The schedule of tests up to a maximum of 6 will continue automatically.