For Long and Trouble-Free Operation: Warning System 111For Long and Trouble-Free OperationWarning SystemWhen an error is detected after the power is turned on or during operation, the (POWER) lamp and a beep sound notifyyou that an error has occurred.Note:If multiple errors occur simultaneously, the one with the highest priority is displayed.1. System error2. Format inconsistency3. Card eject error4. Recording errorWarning DetailsMonitor display Displays the error code.(power) lamp Flashes 4 times per second.Card Access LampBeep sound Repeats rapidly.Warning description A reference signal error or communica-tion error occurred.Recording/playbackoperationStops.Measure Check the error code table and consultwith your dealer.Monitor display Displays the error code.(power) lamp Flashes 4 times per second.Card Access LampBeep sound Repeats rapidly.Warning description SYSTEM mode is internally inconsistentand a restart is required.Recording/playbackoperationNot possibleMeasure Turn the power off and then back on asdescribed in the message and thencheck that an error is not displayed.Monitor display Displays the error code.(power) lamp Flashes 4 times per second.Card Access LampBeep sound Repeats rapidly.Warning description An error occurred in the internal memo-ry of the unit because a P2 card was re-moved during access.Recording/playbackoperationNot possibleMeasure Turn the power off and then back on asdescribed in the message. Check thatthere is no problem with the clips on theremoved card and repair the clips ifnecessary.Monitor display Displays “REC WARNING.”(power) lamp Flashes 4 times per second while re-cording continues.Card Access LampBeep sound Repeats rapidly.Warning description A recording or recording circuit settingerror occurred.Recording/playbackoperationRecording may continue or may stop.Measure Resume recording. Alternatively, turnthe power off and then back on, andthen resume recording.