10988-6-3 BATTERY SETTING2The ____ in the Adjustable Range column indicates the presetmode.Items/Data SavedAdjustableRange RemarksNiCd14 _•Enable selection under BATTERY SELECT._: Enable selection.• : Disable selection.NEAR END 11.0:13.6:15.0Set the NEAR END voltage in 0.1 V steps.END 11.0:13.2:15.0When MANUAL is selected in the menuabove, set the END voltage in 0.1 V steps.– C U F –NiCd13 _•Enable selection under BATTERY SELECT._: Enable selection.• : Disable selection.NEAR END 11.0:12.7:15.0Set the NEAR END voltage in 0.1 V steps.END 11.0:12.2:15.0When MANUAL is selected in the menuabove, set the END voltage in 0.1 V steps.– C U F –NiCd12 _•Enable selection under BATTERY SELECT._: Enable selection.• : Disable selection.NEAR END 11.0:11.5:15.0Set the NEAR END voltage in 0.1 V steps.END 11.0:11.2:15.0When MANUAL is selected in the menuabove, set the END voltage in 0.1 V steps.– C U F –TYPE A _•Enable selection under BATTERY SELECT._: Enable selection.• : Disable selection.FULL 12.0:15.0:17.0Set the voltage to display the FULLindication in 0.1 V steps.NEAR END 11.0:13.6:15.0Set the NEAR END voltage in 0.1 V steps.END 11.0:13.2:15.0When MANUAL is selected in the menuabove, set the END voltage in 0.1 V steps.– C U F –Items/Data SavedAdjustableRange RemarksTYPE B _•Enable selection under BATTERY SELECT._: Enable selection.• : Disable selection.FULL 12.0:13.5:17.0Set the voltage to display the FULLindication in 0.1 V steps.NEAR END 11.0:11.8:15.0Set the NEAR END voltage in 0.1 V steps.END 11.0:11.1:15.0When MANUAL is selected in the menuabove, set the END voltage in 0.1 V steps.– C U F –