584. Input/output signal settings4-1-3. Setting the analog input gainThe user can set the gain when the input signals are analog signals. The setting range is ±30 steps, and the gainchanges by ± dB. The amount of change in the gain when it is changed by one step is not fixed.1 On the Input sub menu, turn [F] to select the input signals using the Signal item.2 Turn [F5] to set the input signal gain using the AnaGain item.4-2. Setting the up-converter (option)The settings for the up-converter contained on the optional SDI input board and analog input board are performedbelow.1 Press the [FUNC] button to light its indicator, and press the [IN/OUT] button to display the IN/OUT menu.2 Turn [F1] to display the UpConvt sub menu.An asterisk () appears at the left of the parameter currently selected.UpConvt Signal Scale↓ MovDet↓ Sharp↓11/11 IN5 SQ 3 3IN5~8 ECLB1~5 1~53 Turn [F] to select the input signal using the Signal item.4 Turn [F3] to select the scaling system using the Scale item, and press the [F3] switch to enter the selection.SQ (squeeze): The image is enlarged both horizontally and vertically to fill the entire screen.EC (edge crop): The aspect ratio of the image is maintained, the image size is increased in accordancewith the vertical resolution, and black bands are added at the left and right.LB (letter box): The aspect ratio of the image is maintained, the image size is increased in accordancewith the horizontal resolution, and the image is cropped at the top and bottom.Input image SQ EC LB5 Turn [F4] to set the image movement detection sensitivity using the MovDet item, and press the [F4] switchto enter the selection.1: Toward still images 3: standard 5: toward moving images6 Turn [F5] to set the extent of the edge sharpness for the images using the Sharp item, and press the [F5]switch to enter the selection.1: Not sharp edges 3: standard 5: very sharp edgesFor details on the other settings, refer to the operating instructions of the optional board.