Cable Compensator AW-RC40036 (E)ENGLISHParts and their function1 Power LEDThis lights up green when the (2) POWER switch is setto ON while a DC 12V voltage is supplied to the (7) DC12V IN socket.2 POWER switchSet this to ON to turn on the cable compensator’s power.Part of the power supply circuitry will still operate evenwhen the power switch is at the OFF position. To turn offthe power completely, disconnect the AC adaptor.3 Cable length setting switches [0 to 5]Set these switches according to the length of the coaxialcable connected. [0] is used to provide the minimumamount of cable compensation, and [5] the maximumamount. As a general guideline, set to [1] if the coaxialcable is 100 meters long, and [2] if it is 200 meters long.4 Y LEVEL controlUse this to adjust the output level of the cablecompensation output signals (video output).5 F RESPONSE controlUse this to adjust the amount of cable compensation(frequency response compensation) for the cablecompensation output signals.6 SHORT/LONG selector switchThis is normally used at the SHORT position. Set it toLONG if the coaxial cable from the camera is a long oneand the camera’s sync adjustment range is insufficient, orif the cable compensator is used as part of a system(another cable compensator is required) in which thecoaxial cable (5C-2V or equivalent) connected to thecamera is longer than 500 meters.7 DC 12V IN socketThis is the power input socket. Connect the AW-PS301 ACadaptor (sold separately) here.8 MONI SEL IN connectorControl signals for selecting the video signals output tothe MONITOR1 or 2 connector are supplied to thisconnector. Connect it to the MONI SEL OUT connectoron AW-RP400 pan/tilt head controller using a 10BASE-Tstraight cable (equivalent to UTP category 5). It is thenpossible to output the video signals of the cameraselected by the AW-RP400 or the AW-CB400 remoteoperation panel which is connected to the AW-RP400, tothe MONITOR1 or MONITOR2 connector.9 G/L IN connectorsThe sync signals (black burst signals) are input here.These connectors are automatically terminated internallyby a 75-ohm resistance. The top and bottom connectorshave the same specifications, and the signals can beconnected to either one. The termination is released ifBNC cables are connected to both input connectors(when they are used in a loop-through configuration).: G/L OUT connectors [1 to 5]The genlock signals supplied to the G/L IN connector canbe distributed and output to five cameras.Use sync signal outputs 1 to 5 to correspond to videosignal channels 1 to 5.The signals of sync signal output connector 1 aresupplied to the camera connected to video inputconnector 1.1 2 3 456 87> = < ? @ A ; : 9 BFront panel Rear panel