Time Delay Safety ControlAutomatic Restarting ControlCompressor Forced Operation Control7 Operation Details7.1. Cooling Mode OperationWhen selecting the Cooling (COOL) Mode Operation, the unit will operate according to the setting by the Remote Control andthe operation is as the following.3 min. --- The Compressor is ceased for 3 minutes to balance the pressure in the refrigeration cycle.(Protection of compressor)7 min. --- The unit will automatically operate in 7 minutes even if the room temperature is not reached.(Protection of raising the humidity)30 sec. --- The compressor is switched ON at once, it is to be operated for 30 seconds.(Protection of compressor)7.2. Soft Dry Mode OperationWhen selecting the Soft Dry (DRY) Mode Operation, the operation will be cooling until the Room Temperature reaches the SetTemp. on the remote control, and then Soft Dry will activate.(During Soft Dry operation, the fan of the indoor unit will operate at Low fan speed and stop at 4-second intervals, and operationwill be switched on and off for up to 10 minutes on and 6 minutes off.)18CS-A12ATP5 CU-A12ATP5 / CS-A18ATP5 CU-A18ATPT5 / CS-A24ATP5 CU-A24ATPT5