Operation DetailsCOOL – Cooling Operation• To set the room temperature at your preferencecooling comfort.AUTO – Automatic Operation• Sense indoor temperature to select the optimummode.• Temperature is not displayed on the remote controlduring AUTO operation.DRY – Soft Dry Operation• A very gentle Cooling Operation, prior todehumidification. It does not lower the roomtemperature.• During Soft Dry operation, the indoor fan operates atLow Fan Speed for 10 minutes (ON and OFF for 4seconds intervals) then OFF for 6 minutes. Thisoperation will be repeated.HEAT – Heating Operation(for Heat Pump Model only)• Heat is obtained from outdoor air to warm up theroom. When the outdoor ambient air temperaturefalls, the heating capacity of the unit might bereduced.• Defrosting OperationDepend on the outdoor temperature, the operationoccasionally stops to melt the frost on the outdoorunit.FAN – Air Circulation Operation(for Cooling Model only)• Heated air rises and collects at the top of the room.The air circulation circulates the heated air downward,thus increasing heating effectiveness. When the unitis installed floor mounted, you should set thetemperature higher than that of ceiling mounted. Setting the Fan Speed• Press 4 to select:-– Low Fan Speed– Medium Fan Speed– High Fan Speed Vertical Airflow Direction Manual Operation• Press and hold the Manual Airflow DirectionSelection Button 5 , then release at the desiredairflow direction.• Cooling / Soft Dry / HeatingThe airflow direction can be adjusted as desiredby using the remote control. This is effectivewhen you want to cool yourself directly, such aswhen coming out of the bath. The louver can beadjusted within a range between the horizontaland 30 degrees downward at Cooling and SoftDry Operation, and between the horizontal and60 degrees downward at Heating Operation. Automatic Operation• Press the Auto Airflow Direction Button 6.• Cooling / Soft DryThe louver will automatically swing up and downto create the feeling of a refreshing breeze.• Heating Setting the Horizontal Airflow Direction Use this air conditioner under the followingconditions:Cooling Model• Adjust it manually Notes• If the unit is not going to be used for an extendedperiod of time, turn off the main power supply. If it isleft at the ON position, approximately 2.0 W ofelectricity will be used even if the indoor unit has beenturned off with the remote control.• If operation is stopped, then restart immediately, theunit will resume operation only after 3 minutes.DBT: Dry Bulb TempWBT: Wet Bulb TempMaximum Temperature-Cooling(Maximum Temperature-Heating)Minimum Temperature-Cooling(Minimum Temperature-Heating)DBT32(30)16(16)WBT23(-)11(-)DBT43(24)16(-5)WBT26(18)11(-6)Indoor Outdoor(Unit in °C)Heat Pump ModelDBT: Dry Bulb TempWBT: Wet Bulb TempMaximum TemperatureMinimum TemperatureDBT3220WBT2314DBT4320WBT2614Indoor Outdoor(Unit in °C)DownwardSwing upand downHorizontalWhen the airflowtemperature is lowDownwardWhen the airflowtemperature become warmHorizontalAt ceiling mounted At floor mountedOFF/ONTEMPMODE FAN SPEEDAUTOTIMERAIR SWINGON/OFF SET/CRESETAUTOCOOLFANFANSPEEDDRYCH HOFF ON OFF ONSLEEP32145 CONVENIENCE OPERATION Sleep Mode OperationTo obtain a comfortable room temperature whilesleeping:-• Press 5.• Sleep mode indicator on the indoor unit will light up.• To cancel this operation, press once more. Sleep Mode Operation Details• When the room temperature reaches the settemperature, the airflow volume will change to lowautomatically.• Sleep Mode Operation time is 5 hours.• When used together with the timer, the timer has apriority.Cooling ModelCARE AND MAINTENANCE Cleaning the Indoor Unit and RemoteControl• Wipe gently with a soft, dry cloth.• Do not use water hotter than 40˚C or polishing fluidto clean the unit. Cleaning the Air Filter(Recommendation:- If the unit is operated in a dustyenvironment, clean the filters every two weeks,continuous use of this dirty filters will reduce coolingor heating efficiency)1 Remove dirt using a vacuum cleaner.2 Wash back of the air filter with water.3 If badly soiled, wash it with soap or a mild householddetergent.4 Let it dry and reinstall it.Be sure the “FRONT” mark is facing you.* Damaged air filter.Consult the nearest authorized dealer.Part No.: CWD00112.• Do not use benzene, thinner, scouring powder orclothes soaked in caustic chemical to clean theunit.HOFFHONHONHOFFHONHOFFSETTING THE TIMERThe Delay ON-Timer and Delay OFF-Timer cannot beselected simultaneously.• Press the Timer Selection Button 1.• Select one of the following five types of operation.Each time the button is pressed, the operation modeis shifted in the arrow direction.Delay OFF Timer Example :Operation Stopsafter 1 hourON Timer.Delay ON Timer Example :Operation starts after6 hours.Delay OFF and Example :ON Timer Operation stops after1 hour and re-startsafter another 5 hours.Delay ON and Example :OFF Timer Operation starts after10 hours, and thenstops after another 8hours.• Then press the Timer Setting Button 2 or 3 to thedesired number of hours.(Number of hours which can be set : 1 ~ 12)• Press the Timer Set/Cancel Button 4Heat Pump Model← 1 hour →Sleep shiftoperation starts.Approx. 3°Cdecrease.• Cooling or Soft DryOperation for sleep shiftoperation will start toavoid overcooling.• Heating operation forsleep shift operation willstart to avoid overheating.SleepOperationbutton ispressed.0~1 hourApprox. 2°Cdecrease.Approx.1°Cincrease.Approx. 1°Cincrease.TemperatureSettingTemperatureTime← 1 hour →after approx. 5 hours of sleep shiftoperation, it will stop automatically.TimeApprox. 1°Cincrease.TemperatureSleepOperationbutton ispressed.Sleep shiftoperationstarts.0~1 hour ← 1 hour →after approx. 5 hours of sleep shiftoperation, it will stop automatically.Approx.1°Cincrease. • Cooling or Soft DryOperation for sleep shiftoperation will start toavoid overcooling.SettingTemperatureWhen the room temperaturebecome a level ideal forsleep, the operation 10minutes on and 20 minutesoff will be repeated.23CS-A12ATP5 CU-A12ATP5 / CS-A18ATP5 CU-A18ATPT5 / CS-A24ATP5 CU-A24ATPT5