42ii Auto Fan Speed[Cooling, Dry] According to room temperature and setting temperature, indoor fan speed is determined automatically. When set temperature is not achieved, the indoor fan will operate according to pattern below. When set temperature achieved, the indoor fan speed will be fixed. When thermostat off, the fan stop periodically.[Heating] According to indoor pipe temperature, automatic heating fan speed is determined as follows.B. Feedback control Immediately after the fan motor started, feedback control is performed once every second. During fan motor on, if fan motor feedback ≥ 2550 rpm or < 50 rpm continue for 10 seconds, then fan motor errorcounter increase, fan motor is then stop and restart. If the fan motor counter becomes 7 times, then H19 - fanmotor error is detected. Operation stops and cannot on back.12.3 Outdoor Fan Motor Operation It starts when compressor starts operation and it stops 30 seconds after compressor stops operation.ON ONCompressor OFFON Fan Speed ONOutdoor Fan 30 sec OFFa b c d e f g h[1 pattern : 10 s]a bHigherFanSpeedMediumLowerRPM IncreasedRPM MaintainRPM ReducedOFFIndoor Pipe Temp.40°C (104°F)19°C (66.2°F)35°C (95°F)16°C (60.8°F)