Indoor UnitAutomatic Operation Switch• Press for < 5s to run Automatic Operation.(Used when the remote control cannot be used.)• Press continuously for 5s and < 8s to runForced Cooling Operation.• Press continuously for 8s and < 11s torun Forced Heating Operation.• Press continuously for 11s and < 16s tochange different remote controllingsetting (A↔B Mode).• Press continuously for 16s or < 21s toswitch OFF / ON Remote ControlReceiving Sound or H14 AbnormalityDetection Mode.Operation Indication Lamps (LED)Quiet ModeFive Operation Modes• Automatic, Heating, Cooling, Soft Dryand Fan Operation.Delay ON Timer and OFF TimerPowerful Mode• For quick cooling or heating.• POWER (Green) ...... Lights up duringMONITOR compressor operation.• (Green) ............ Lights up in IonizerMode Operation.• POWER (Green) ...... Lights up inoperation, blinks inAutomatic OperationMode judging and HotStart operation.• TIMER (Orange) .... Lights up in TimerSetting.Blinks in SelfDiagnosis Control.• QUIET (Orange) .... Lights up in QuietMode Operation.• POWERFUL (Orange) ... Lights up whenPowerful Mode isselected.Automatic and 5 Manual IndoorFan SpeedsAutomatic and 5 Manual VerticalAirflow DirectionsAutomatic and 5 Manual HorizontalAirflow DirectionsAutomatic Restart Control• Operation is restarted after power failureat previous setting mode.Microcomputer-controlled RoomTemperature Control• To provide extra quiet operation.Ionizer Control• Ionizer control for generate negative ionin discharge air.4CS-E9CKP CU-E9CKP5 / CS-E12CKP CU-E12CKP5Panasonic ilmalämpöpumput korjaa ja huoltaa pääkaupunkiseudulla: Jäähdytinpalvelu RefGroup Oywww.ilmalämpöpumput.com