31(c) Heating Operation12.1.5. ON Timer ControlON timer can be set using remote control, the unit with timer set will start operate earlier than the setting time. This is to provide acomfortable environment when reaching the set ON time.60 minutes before the set time, indoor (at fan speed of Lo-) and outdoor fan motor start operate for 30 seconds to determine theindoor intake air temperature and outdoor air temperature in order to judge the operation starting time.From the above judgment, the decided operation will start operate earlier than the set time as shown below.12.1.6. OFF Timer ControlOFF timer can be set using remote control, the unit with timer set will stop operate at set time.12.1.7. Auto Restart Control1. When the power supply is cut off during the operation of air conditioner, the compressor will re-operate within three to fourminutes (there are 10 patterns between 2 minutes 58 seconds and 3 minutes 52 seconds to be selected randomly) afterpower supply resumes.2. This type of control is not applicable during ON/OFF Timer setting.12.1.8. Ionizer OperationPurposeTo provide fresh air effect to users by discharging minus ion to air.Control Condition