3112.3.5 Automative Restart ControlWhen the power supply is cut off during the operation of air conditioner, the compressor will re-operate within three tofour minutes after power supply resumes.12.3.6 Indication PanelLED POWER TIMER POWERFUL QUIETColor Green Orange Red GreenLight ON Operation ON Timer setting ON Powerful Mode ON Quiet mode ONLight OFF Operation OFF Timer setting OFF Powerful Mode OFF Quiet mode OFFNote:ϥ If POWER LED blinks, the possible operation of the unit is operation mode judgment, or ON timersampling.ϥ If Timer LED blinks, there is an abnormal operation occurs.12.3.7 Timer controlDelay ON Timer ca be set using remote controller, the unit with timer set will start operate earlier than the setting time.This is to provide a comfortable environment when reaching the set On time. Seventy minutes before the set time forON Timer or ON-OFF Timer setting, indoor ( at fan speed of Lo-) and outdoor fan motor start operate for 30 secondsto determine the indoor intake air temperature and outdoor air temperature in order to judge the operation mode.From the above judgment, the decided operation will start operate earlier than the set time as shown below.Timer Signal Receiving sound During Operation.Timer Signal Receiving Sound When the Air Conditioner Stops.35