3CAUTIONWARNINGWARNING1. Safety Precautions• Read the following “SAFETY PRECAUTIONS” carefully before perform any servicing.• Electrical work must be installed or serviced by a licensed electrician. Be sure to use the correct rating of thepower plug and main circuit for the model installed.• The caution items stated here must be followed because these important contents are related to safety. Themeaning of each indication used is as below. Incorrect installation or servicing due to ignoring of the instructionwill cause harm or damage, and the seriousness is classified by the following indications.This indication shows the possibility of causing death or serious injuryThis indication shows the possibility of causing injury or damage to properties.• The items to be followed are classified by the symbols:• Carry out test run to confirm that no abnormality occurs after the servicing. Then, explain to user the operation,care and maintenance as stated in instructions. Please remind the customer to keep the operating instructions forfuture reference.1. Engage dealer or specialist for installation. If installation done by the user is defective, it will cause water leakage,electrical shock or fire.2. Install according to this installation instructions strictly. If installation is defective, it will cause water leakage, electricalshock or fire.3. Use the attached accessories parts and specified parts for installation. Otherwise, it will cause the set to fall, waterleakage, fire or electrical shock.4. Install at a strong and firm location which is able to withstand the set’s weight. If the strength is not enough or installationis not properly done, the set will drop and cause injury.5. Do not install outdoor unit near handrail of veranda. When installing air-conditioner unit at veranda of high rise building,child may climb up to outdoor unit and cross over the handrail and causing accident.6. For electrical work, follow the local national wiring standard, regulation and this installation instruction. An independentcircuit and single outlet must be used. If electrical circuit capacity is not enough or defect found in electrical work, it willcause electrical shock or fire.7. This equipment is strongly recommended to be installed with Earth Leakage Circuit Breaker (ELCB) or Residual CurrentDevice (RCD). Otherwise, it may cause electrical shock and fire in case equipment breakdown or insulationbreakdown.8. This equipment must be properly earthed. Earth line must not be connected to gas pipe, water pipe, earth of lightningrod and telephone. Otherwise, it may cause electrical shock in case equipment breakdown or insulation breakdown.9. Do not use joint cable for indoor/outdoor connection cable. Use the specified Indoor/Outdoor connection cable, refer toinstallation instructions CONNECT THE CABLE TO THE INDOOR UNIT and connect tightly for indoor / outdoorconnection. Clamp the cable so that no external force will be acted on the terminal. If connection or fixing is notperfect, it will cause heat up or fire at the connection.10. Wire routing must be properly arranged so that control board cover is fixed properly. If control board cover is not fixedperfectly, it will cause fire or electrical shock.11. When carrying out piping connection, take care not to let air substances other than the specified refrigerant go intorefrigeration cycle. Otherwise, it will cause lower capacity, abnormal high pressure in the refrigeration cycle, explosionand injury.12. Do not use unspecified cord, modified cord, joint cord or extension cord for power supply cord. Do not share the singleoutlet with other appliances. Poor contact, poor insulation or over current will cause electrical shock or fire.13. • For R410A models, when connecting the piping, do not use any existing (R22) pipes and flare nuts. Using suchsame may cause abnormally high pressure in the refrigeration cycle (piping), and possibly result in explosion andinjury. Use only R410A materials.• Thickness or copper pipes used with R410A must be more than 0.8 mm. Never use copper pipes thinner than 0.8 mm• It is desirable that the amount of residual oil is less than 40 mg/10 m.14. During installation, install the refrigerant piping properly before running the compressor. Operation of compressorwithout fixing refrigeration piping and valves at opened condition will cause suck-in of air, abnormal high pressure inrefrigeration cycle and result in explosion, injury etc.15. During pump down operation, stop the compressor before remove the refrigeration piping. Removal of refrigerationpiping while compressor is operating and valves are opened will cause suck-in of air, abnormal high pressure inrefrigeration cycle and result in explosion, injury etc.Symbol with white background denotes item that is PROHIBITED from doing.Symbol with dark background denotes item that must be carried out.