36Power Button pressedPIPINGTEMP.(COOLING)FAN SPEED( rpm)ONOFFAUTO45 seconds20 ‘Shi20 ‘Fast Cooling Cooling, Soft DryMin.5’CorrectionFactor( )℃ -0.25+0.25-1.67-1.00ABCD20 ‘ 20 ‘1130 (Max)730 (Min.)2. For Heating mode:Power Button pressedONOFFAUTO45 seconds20 ‘Shi20 ‘Fast Heating1 HeatingMin.5’+0.25+0.25+2+1.00ABCD20 ‘ 20 ‘1270 (Max)940 (Min.)PIPINGTEMP.(COOLING)FAN SPEED( rpm)CorrectionFactor( )℃Note: The value of A, B, C, D will change according to the indoor temperature.12.3.5 Automatic Restart ControlWhen the power supply is cut off during the operation of air conditioner, the compressor will re-operate within three tofour minutes after power supply resumes.12.3.6 Indication PanelLED POWER TIMER QUIET POWERFULColor Green Orange GREEN REDLight ON Operation ON Timer setting ON Quiet mode ON Powerful mode ONLight OFF Operation OFF Timer setting OFF Quiet mode OFF Powerful mode OFFNote:● If POWER LED blinks, the possible operation of the unit is operating mode judgment, or ON timersampling.● If Timer LED blinks, there is an abnormal operation occurs.12.3.7 Timer controlDelay ON Timer can be set using remote controller, the unit with timer set will start operate earlier than the settingtime. This is to provide a comfortable environment when reaching the set On time. Seventy minutes before the settime for ON Timer or ON-OFF Timer setting, indoor ( at fan speed of Lo-) and outdoor fan motor start operate for 30seconds to determine the indoor intake air temperature and outdoor air temperature in order to judge the operationPIPINGTEMP(HEATING)