9.4. Airflow Direction ControlVertical louver is controlled with Vertical Airflow Direction button on remote controller and by operation conditions, as shown in thetable below.9.4.1. Vertical Airflow Louver AngleCooling and Dry OperationsAirflow Direction Auto Airflow Direction SettingManual Operation Vertical Auto Operation Powerful-ON•••• It swings when airflow direction is set withremote controller.•••• It does not swing while indoor fan isstopped. (It is fixed at the upper limit.).•••• The louver is fixed at five-level settingposition when the airflow direction is set withremote controller.Heating OperationAirflow Direction Auto Airflow Direction SettingFixed by Heat Exchanger Temperature Powerful Operation Remote Control•••• When Heat Exchanger Temperature is lessthan 33°C•••• When Heat Exchanger Temperature isbetween 33°C (, incl.) and 127°C•••• When Heat Exchanger Temperature is lessthan 33°C•••• When Heat Exchanger Temperature isbetween 33°C (, incl.) and 127°C•••• The louver is fixed at five-level settingposition when the airflow direction is set withremote controller.Airflow Direction Auto Airflow Direction SettingOdour Removal Control•••• The vertical louver is fully opened and move to the setting position when the unit is turned on with the remote controller.•••• The vertical louver remains open position when the unit is turned off during operation.•••• The horizontal louver is manually operated.23CS-TE9DKE CU-TE9DKE / CS-TE12DKE CU-TE12DKE