•••• Airflow direction, Fan speed and Setting temperature areoptimized.•••• “Intake Air temperature - Remote controller settingtemperature” is detected every 20 seconds by indicationfrom indoor unit and controlled to each area.Quick Cooling → Unit forcibly turns to Quick Cooling operationfor 5 minutes after POWERFUL ON even through it is in thestable area. If unit gets out of the Quick Cooling area, it turnsto Chilly Cooling operation.Chilly Cooling → Discharge Air temperature is kept low bychanging fan speed according to room temperature and chillyfeeling is produced.2. Maximum Cooling PowerWhen cooling load is big, if fan speed: “SHi” and temp: 16 °C are set, fan speed will be increased for 30 minutes after operationstarts in order to decrease room temperature quickly. (Refer to “Indoor fan speed control” for each model.)3. Dew Condensation Prevention ControlFan speed will be reduced if Dew Condensation Prevent Control is operated.4. Forced Cooling OperationFan speed at Forced Cooling operation with the Emergency Operation button is “Hi”. (Refer to "Indoor fan speed control" foreach model.)5. Emergency OperationFan speed when operation with the Emergency Operation button or Cooling operation with remote controller duringperformance of breakdown diagnosis (breakdown that emergency operation is possible) is “ Me+”. (Refer to "Indoor fan speedcontrol" for each model.)9.6.3. Dry Operation1. Basic Fan SpeedIn the cooling mode area, fan operates in the same speed as cooling operation mode. In the dry mode area, it is switched to"SLo". (Refer to "Indoor fan speed control" for each model.) In the Thermostat-OFF mode, fan stops for 5.5 minutes and afterthat, operates at a speed of level 3.2. Automatic Fan SpeedOdour Cut Control functions and fan operates repeatedly between the 60-second stop and the 30-second “SLo” operations. Inthe beginning of unit operation and Thermostat-ON, fan stops for 40 seconds.9.6.4. Heating Operation1. Hot Start & Cold DraftWhen Indoor Exchanger Temperature is low at the beginning of the operation, fan is stopped. Cold Draft is prevented byincreased Exchanger temperature in proportion to fan speed.2. Auto Fan SpeedIn Auto Fan Speed, fan speed is controlled according to Exchanger temperature. (Refer to "Indoor fan speed control" for eachmodel.)3. Forced Heating OperationFan speed at Forced Heating operation with the Emergency Operation button is "Hi". (Refer to "Indoor fan speed control" foreach model.)4. Fan speed when operation with the Emergency Operation button or Heating operation with remote controller duringperformance of breakdown diagnosis (breakdown that emergency operation is possible) is " Me+". (Refer to "Indoor fan speedcontrol" for each model.)9.7. Powerful OperationIf the POWERFUL button is pressed during operating in Cooling, Heating, Dry or AUTO, unit always forces to operaterespectively in Quick Cooling, Dry and Quick Heating for 5 minutes, which fan speed is "SHi" even though unit is in each stablearea.9.7.1. Cooling Operation29CS-TE9DKE CU-TE9DKE / CS-TE12DKE CU-TE12DKE