2. To remove the Electronic Controllers:• Release the 2 Particular Piece. (Fig. 3)• Release the earth wire screw. (Fig. 3)• Release the screw holder terminal board. (Fig. 3)• Release the CN-DISP connector. (Fig. 3)• Release the CN-TH connector. (Fig. 4)• Release the CN-ION connector. (Fig. 4)• Release the CN-SONIC connector. (Fig. 4)• Release the CN-STM1 connector. (Fig. 4)• Release the CN-STM2 connector. (Fig. 4)• Release the hooks that hold the Electronic Controllerand pull out the Electronic Controller. (Fig. 4)• Release the CN-FM connector. (Fig. 4)• Release the AC01 (white) connector. (Fig. 4)• Release the two RY-PWR connector. (Fig. 4)1. In order to remove the Cross Flow Fan and Indoor FanMotor, Control Board need to be taken out by releasing allthe connectors as indicated below.a. Release the Earth Wire screw. (Fig. 5)b. Release the CN-TH connector. (Fig. 5)c. Release the CN-ION connector. (Fig. 5)d. Release the CN-SONIC connector. (Fig. 5)e. Release the CN-STM1 connector. (Fig. 5)f. Release the CN-STM2 connector. (Fig. 5)g. Release the CN-DISP connector. (Fig. 5)h. Pull out the Drain Hose from outlet to remove theDischarge Grille. (Fig. 5)2. Release the ION connectors. (Fig. 6)3. Release the 3 screws. (Fig. 6)4. By pressing down the hook at the left, you will be able toremove the Control Board. (Fig. 6)Fig. 3Fig. 4Fig. 5Fig. 612.3. Cross Flow Fan and Indoor Fan Motor Removal Procedures56CS-V18DKE CU-V18DKE / CS-V24DKE CU-V24DKE