ENGLISH11The unit stops and the TIMERTIMER indicator blinks.indicator blinks.Press INFO button to retrieveerror codeExample of error coderetrieve successfully.If failed to received signal from indoor unit “PRESS AGAIN”will be shown for 4 seconds, repeat previous step.ERROR F99 PRESSAGAINTurn the unit off and reveal the error code toauthorized dealer.9 AUTO OFF/ON BUTTON• Use when remote control is misplaced or a malfunctionoccurs.Action ModePress once. AutoPress and hold until 1 beep is heard,then release. CoolingPress and hold until 1 beep is heard,then release.Press again until 2 beeps, then release.HeatingPress the button to turn off.10 AIR FILTERS• Clean the filters regularly.• Wash/rinse the fi lters gently with water to avoid damageto the filter surface.• Dry the fi lters thoroughly under shade, away from fire ordirect sunlight.• Replace any damaged filters.How to remove the air filters:1121. Put a fi nger in the depressed portions on both sides.2. Pull the fi lter towards you while pushing in thedepressed portion.How to install the air filters:1122331. Hold the air filter along © on the indoor unit. Put the airfi lter inside the top rails on both sides.2. Push ►◄ (both sides) in the middle of the air filter atthe same time until a click is heard.3. Push ■ (both sides) at the lower part of the air fi lter atthe same time until a click is heard.11 nanoe-G GENERATORClean with dry cotton bud.• nanoe-G generator cleaning isrecommended every 6 months.F568728_YB0512-1062.indb 11F568728_YB0512-1062.indb 11 6/11/2012 9:43:35 AM6/11/2012 9:43:35 AM