Cooling or Soft Dry OperationPurpose is to obtain a comfortable room temperature whilesleeping. When you press the SLEEP Mode, the followingmovement will start to avoid overcooling.•••• Sleep shift operation starts, when the room temperaturereaches the setting temperature or after 1 hour of operation.•••• The setting temperature will be risen by 0.5°C at the start ofoperation and by 0.5°C one hour later .•••• The airflow volume will automatically change to Lo- fanspeed.•••• Sleep Mode operation time is 8 hours, the operation will bestop after 8 hour.•••• When used together with the Timer, the Timer has priority.Present Judgement Next ModeMode Cooling Soft Dry HeatingO OCooling 23°C Cooling (Judgement: Not Applicable (Judgement:Heating 23°C & Above) Below 23°C)O OSoft Dry 23°C Soft Dry Not Applicable (Judgement: (Judgement:Heating 23°C & Above) Below 23°C)O OHeating Cooling (Judgement: Not Applicable (Judgement:23°C Heating 23°C & Above) Below 23°C)Automatic Set TemperatureRefer 3. as below.3. Automatic Set TemperatureFor each operation, set temperature will automatically set as shown below.However it can be selected 2°C higher or 2°C lower from standard set temperature by pressing the “Room Temperature Settingbutton”.Operation Hi (Standard) Lo(+2°C) (±0°C) (-2°C)Cooling 27°C 25°C 23°CSoft Dry 24°C 22°C 20°CHeating 23°C 21°C 19°C•••• The mode judging temperature and standard setting temperature can be increased by 2°C, by open the circuit of JX6 atindoor electronic controller.7.5. Sleep Mode Auto Operation32CS-W12CTP CU-W12CTP5 / CS-W18CTP CU-W18CTP5 / CS-W24CTP CU-W24CTP5