3-44Control of 2WAY SYSTEM1234567893. Timer Remote ControllerOuting function is a function that prevents the room temperature from increasing too much (or decreasing too much) when noone is in the room.An air conditioner works automatically if this function is set effective.COOL / DRYRoom temperatureRoom temperatureFor ExampleSetting at Outing Temperature 30Outing function Upper limitHEATOuting function Lower limitThe air conditioner starts operation when the room temperature decreases up to +1 of the lower limit.The air conditioner stops operation when the room temperature increases up to +2 of the lower limit.The air conditioner starts operation when the room temperature increases up to –1 of the upper limit.The air conditioner stops operation when the room temperature decreases up to –2 of the upper limit.[Precautions]The outing control only starts/stops the air conditioner. It does not change the operation mode/temperature setting.Therefore, the operation mode/temperature needs to be set beforehand so that the outing function turns on the air condition-er with your desired operation mode/ temperature setting.If the room temperature rapidly changes, the room temperature may get over the upper or lower limit when the outing func-tion is activated.The outing function is invalid during FAN/AUTO operation mode.The air conditioner's stop order (stated in /above) is valid only when the outing function is operated.If operated using other remote control unit (or a centralized control device such as a system control), the outing function doesnot work.(ON)(ON)(OFF)(OFF)2211302928141312For ExampleSetting at Outing Temperature 12(Setting at Outing Temperature)(Setting at Outing Temperature)General Performance of the Outing FunctionOuting Function