Dimensions: 430 (W) x 405 (D) x 59.7 (H) mmMass: 4.1kgPower consumption in standby mode: approx. 0.6 WNote:1. Specifications are subject to change without notice.Mass and dimensions are approximate.2003 Panasonic AVC Networks Singapore Pte. Ltd. All rightsreserved. Unauthorized copying and distribution is a violation oflaw.1. Before Repair and AdjustmentDisconnect AC power, discharge Power Supply Capacitors C1011 & C1012 through a 10 , 5Wresistor to ground.DO NOT SHORT-CIRCUIT DIRECTLY (with a screwdriver blade, for instance), as this maydestroy solid state devices.After repairs are completed, restore power gradually using a variac, to avoid overcurrent.Current consumption at AC 220V-240V in NO SIGNAL mode should be ~163 mA .2. Safety Precautions2.1. General Guidelines1. When servicing, observe the original lead dress. If a short circuitis found, replace all parts which have been overheated ordamaged by the short circuit.2. After servicing, see to it that all the protective devices such asinsulation barriers, insulation papers shields are properlyinstalled.3. After servicing, make the following leakage current checks toprevent the customer from being exposed to shock hazards.2.1.1. Leakage Current Cold Check1. Unplug the AC cord and connect a jumper between the twoprongs on the plug.2. Measure the resistance value, with an ohmmeter, between thejumpered AC plug and each exposed metallic cabinet part on the3