Unit Settings andData Writing4-64.2.2 Unit Setting and Conversion Processing TimeConversion time varies with the configuration setting conditions. Conversion processing execution/non-execution setting and conversion processing timeSelect the execution or non-execution of the conversion processing of analog output on achannel-by-channel basis. This can save the conversion time for channels that do not executeconversion processing. A conversion time of 25 μs is required per channel.Example) Conversion time for four channelsConverted in the order of ch0→ch1→ch2→ch3→ch0→ch1→ch2→ch3→.... (1 cycle = 100 μs)Example) Conversion time for two channels (with CH2 and CH3 excluded).Conversion is executed in the order of ch0→ch1→ch0→ch1→ch0→ch1→ch0→ch1→...and the conversion time for CH2 and CH3, which are excluded, is saved. (1 cycle = 50 μs)