1MOUNTING2How to mount1. Fit the rear part of the mounting section of theamplifier on a 35mm width DIN rail.2. Press down the rear part of the mounting sec-tion of the unit on the 35mm width DIN rail andfit the front part of the mounting section to theDIN rail.Note: Take care that if the front part is lifted without pushing the amplifier forward, the hookon the rear portion of the mounting section is likely to break.How to remove1. Push the amplifier forward.2. Lift up the front part of the amplifier to remove it.235mm width DIN rail2 1PART DESCRIPTION1Jog switch MODE keyPress Turn to “+” side Turn to “-” side PressTo decide each item. To select each item.To select a modeor to cancel duringsetting.Select 1 indicator (Yellow) Select 2 indicator (Yellow)Output 1 operation indicator(Orange)Output 2 operation indicator(Orange)Jog switchMODE keyMODE indicator: TEACH (Yellow)MODE indicator: RUN (Green)MODE indicator: CUSTOM (Yellow)MODE indicator: TIMER (Yellow)Digital display(Green / Red)MODE indicatorL/D (Yellow)Laser emission indicator(Green)MODE indicatorPRO (Yellow)Note: Do not pull by holding the cable without pressing the release lever, as this can causecable break or connector break.How to remove1. Remove the connector cover.2. Pressing the release lever attached to theconnector of the sensor head, pull out theconnector.How to connect1. Insert the connector of the sensor headLS-H series (optional) into the connectorarea for the sensor head of this product asshown in the right figure.2. Fit the connector cover.CONNECTION OF A SENSOR HEAD3Make sure that the power supply is OFF while connecting or disconnect-ing the sensor head LS-H series (optional).Terminal No. Connection cable1 Cable core: Brown Cable color: Gray2 Shielded wire3 Cable core: Yellow Cable color: Black4 Shielded wire3214Connector area forthe sensor headConnector of thesensor head LS-Hseries (Optional)Connector cover2 1Release leverFor details of the setting contents or setting procedures, refer to “LS seriesPRO mode operation guide” in “Panasonic Industrial Devices SUNXwebsite (http://panasonic.net/id/pidsx/global).”Thank you very much for purchasing Panasonic products. Please read thisInstruction Manual carefully and thoroughly for the correct and optimumuse of this product.Kindly keep this manual in a convenient place for quick reference.WARNING● Never use this product as a sensing device for personnel protection.● In case of using devices for personnel protection, use products whichmeet laws and standards, such as OSHA, ANSI or IEC etc., for person-nel protection applicable in each region or country.● In case of control or adjustment using procedures other than thosespecified in this instruction manual, hazardous laser radiation exposurecan result.1. Holding the connector of the quick-connec-tion cable, align its release lever with thegroove at the top portion of the controllerconnector.2. Insert the connector till a click is felt.WIRING4How to connectNote: Take care that if the connector is pulled out without pressing the release lever, the re-lease lever may break. Do not use a quick-connection cable whose release lever hasbroken. Further, do not pull by holding the cable, as this can cause a cable-break.How to remove1. Pressing the release lever at the top of thequick-connection cable connector, pull outthe connector.Make sure to connect or disconnect the quick-connection cable (optional)in the power supply OFF condition.Quick-connectioncable (Optional)Groove ReleaseleverReleaseleverTerminal No. Terminal name1 +V2 Output 13 0V4 Output 22134AMPLIFIER CASCADING5For mounting and removing the amplifier, refer to “ MOUNTING.”● Make sure that the power supply is OFF while adding or removing the amplifier.● Make sure to check the allowable ambient temperature, as it dependson the number of amplifiers connected in cascade.● In case 2 or more amplifiers are connected in cascade, make sure tomount them on a DIN rail.● When the amplifiers move on the DIN rail depending on the attaching con-dition or the amplifiers are mounted close to each other in cascade, fit thembetween the end plates MS-DIN-E (optional) mounted at the two ends.● Up to maximum 15 amplifiers can be added (total 16 amplifiers con-nected in cascade).● When connecting 2 or more amplifiers in cascade, use the sub cableCN-72-C□ (optional) as the quick-connection cable for the second am-plifier onwards.● When connecting amplifiers not close to each other in parallel, be sure tomount the end plate MS-DIN-E (optional) at both sides of each amplifier.● When this product and other products (e.g. fiber sensoramplifiers, pressure sensor controllers, etc.) are con-nected together in cascade, install those products sothat they are in order of Group A, B, and C as shown inthe right figure. This product is included in Group C.● As for the products that are located between differ-ent groups, put the amplifier protection seal FX-MB1(optional) on the communication window of eachcorresponding product.● Within each group, identical models should beconnected in a lump.● When this product and other products (fiber sensor amplifiers, pressuresensor controllers, etc.) are connected together in cascade, items thatcan be copied at Copy setting are limited.Copiable items are digital display setting in RUN mode, Eco setting,time period hold setting and CUSTOM setting.Communication directionGroupAGroupBGroupCSlide1. Mount the amplifiers, one by one,on the 35mm width DIN rail.2. Slide the amplifiers next to eachother, and connect the quick-connection cables.3. Mount the end plates MS-DIN-E (op-tional) at both the ends to hold theamplifiers between their flat sides.4. Tighten the screws to fix the endplates.How to cascadeEnd plateMS-DIN-E (Optional)Sub cableCN-72-C□ (Optional)Main cableCN-74-C□ (Optional)End plateMS-DIN-E (Optional)Communication windowINSTRUCTION MANUALDigital Laser Sensor Amplifier LS-403ME-LS403 No.0084-50V