32-point teachingThe basic teaching method when the sensing object is present is 2-pointteaching.Thru-beam type Specular reflective type Reflective type1.2.1.2.1. 2.1. Press the SET key when the sensing objectis present (system command / Index2: 0x43).2. Press the SET key when the sensing objectis absent (system command / Index2: 0x44).Display when stable sensing is possible.Display when stable sensing is not possible.Limit teachingWhen the sensing object is small or there are objects in the background,use this teaching method.Sensing object is present Sensing object is not present1. Press the SET keywhen the sensingobject is present ornot present.2. Use the instructions according to your sensor type:• Thru-beam type, specular reflective type: Press the UP key to shift thethreshold level to a high level (low sensitivity) or press the DOWN keyto shift the threshold level to a low level (high sensitivity) (Notes 1, 2).• Thru-beam type, specular reflective type: Press the UP key to shift thethreshold level to a high level (low sensitivity) or press the DOWN keyto shift the threshold level to a low level (high sensitivity) (Notes 1, 2).• Reflective type: Press the DOWN key to shift the threshold level to ahigh level (low sensitivity) or press the UP key to shift the thresholdlevel to a low level (high sensitivity) (Notes 1, 2).Display when stable sens-ing is possible.Display when stable sens-ing is not possible.Notes:1. The shift value of approx. 15% is an initial value. Display of the shift value can bechanged to percentage [approx. 0 to 999% (unit 1 %)] or incident light intensity [0to 9999 (unit 1)].For setting the shift amount, refer to in section 12 “PRO MODE”.2. At the time of limit teaching. UP key (System command / Index2: 0x4B)DOWN key (System command / Index2: 0x4C)Auto teachingWhen the sensing object is moving, use thisteaching method.1. Press and hold the SET key for a long time2. Run the sensing object on the productionline and hold down the SET key (systemcommand / Index2: 0x47) .3. The display shows in green. Whenthe sensing object has passed through,release the SET key (system command /Index2: 0x48).Display when stable sensing is possible.Display when stable sensing is not possible.8 Threshold value fine adjustment function● The fine adjustment of the threshold value can be set in RUN modeand during IO-Link communication.1. 2. 1. Press the UP key to in-crease the threshold value2. Press the DOWN key todecrease the threshold value3. 3.4. 4.3. Press the SET key to savethe threshold value.4. The value has been saved.If you do not press theSET key, the value will besaved automatically after 2seconds.9 Key lock functionThe key lock function protects settings from being changed inadvertently.The function can also be activated via IO-Link communication. When thekey lock function is activated and you press any of the keys, the digitaldisplay shows .Activating the key lock function1. Press the SET and the MODE key together for3 seconds or longer.The digital display changes to show the keylock function has been activated.Then the digital display returns to show thecurrent values.Deactivating the key lock function1. Press the SET and the MODE key together for3 seconds or longer.The digital display changes to show the keylock function is active.The digital display changes to show the keylock function has been turned off.Then the digital display returns to show thecurrent values. PreviousNext |