Item DescriptionCounter of Digital TrunkError Logs logged in"Minor Error" LogOut of SYNC (#300) Digital CO line out of sync (Loss of Signal)RAI (#301) Digital CO line RAI signal receptionAIS (#302) Digital CO line Alarm Indication SignalreceptionFrame Failure (#300) Digital CO line frame failure (Loss of Frame)Counter of minorcommunication errorCRC Cyclic Redundancy Check errorSF Severely errored frame (or Severe FramingError)FE Frame synchronization bit-errorLV Line Code ViolationSL Controlled slipTo view digital CO line information1. From the Utility menu, select Digital Trunk Error Report.2. From the Slot No drop-down list, select the target slot.• To generate a report on a specific card, select the slot number and card name.• To generate a report on all matching cards simultaneously, select "ALL".3. From the Display form drop-down list, select the time period to view.4. Click Execute.The error report will be displayed.2.6.14 Utility—IP Extension Statistical InformationDisplays accumulated statistical information on IP extensions, IP-EXT cards, V-IPEXT32 cards, V-IPCS4cards, and the DSP card.The displayed items are as follows:Item DescriptionCollection Started Time Date and time the port was last reset.Port No. Number of the port.RTP Receive Packet Counter Total number of packets received.RTP Receive Lost Packet Counter Total number of packets lost.RTP Receive Abandoned Packet Counter Total number of packets abandoned.RTP Arrive Packet Interval (MAX.) [ms] Maximum time taken for a packet toarrive.RTP Arrive Packet Interval (MIN.) [ms] Minimum time taken for a packet toarrive.60 PC Programming Manual Document Version 2011-102.6.14 Utility—IP Extension Statistical Information