17 CIRCUIT OPERATION (HANDSET)17.1. OutlineHandset consists of the following ICs as shown in BLOCK DIAGRAM (HANDSET) (P.46).•••• DECT BBIC (Base Band IC): IC4−−−− All data signals (forming/analyzing ACK or CMD signal)−−−− All interfaces (ex: Key, Detector Circuit, Charge, DC/DC Converter, EEPROM, LCD)•••• RF Module: IC3−−−− PLL Oscillator−−−− Detector−−−− Compress/Expander−−−− Amplifier for transmission and reception•••• EEPROM: IC2−−−− Temporary operating parameters (for RF, etc.)17.2. Power Supply Circuit/Reset CircuitCircuit Operation:When power on the Handset, the voltage is as follows;BATTERY (2.2 V ~ 2.6V: TP3) → 4.0V → IC3 (6, 25), D3 → IC4 (37) → IC4 (39, 63) (2.65V)The Reset signal generates R19, C23 and 2.65V.17.3. Charge CircuitCircuit Operation:When charging the handset on the Base Unit, the charge current is as follows;DC+ (5.5V ~ 6V) → D4 → R43, R44 → CHARGE+ (Base) → CHARGE+ (Handset) → L4 → Q2→ F1 → BATTERY+... Battery...BATTERY- → R21 → GND → L5 → CHARGE- (Handset)→ CHARGE- (Base) → GND → DC- (GND)In this way, the BBIC on Handset detects the fact that the battery is charged.The charge current is controlled by switching Q2 of Handset.Refer to Fig.101 in Power Supply Circuit (P.44).17.4. Battery Low/Power Down DetectorCircuit Operation:“Battery Low” and “Power Down” are detected by BBIC which check the voltage from battery.The detected voltage is as follows;•••• Battery LowBattery voltage: V (Batt) < 2.3VThe BBIC detects this level and “ ” starts flashing and “battery alarm” starts ringing.•••• Power DownBattery voltage: V (Batt) < 2.2VThe BBIC detects this level and power down.47KX-TG1105RUS / KX-TG1105RUT / KX-TG1106RUS / KX-TG1106RUT / KX-TGA110RUS / KX-TGA110RUT