(*1) When adding “01” (hex) to default value, sending levelincreases by 1.0dB.ex.)Item Default Data New Data1C 1D 1BSending level -7.5dBm -6.5dBm -8.5dBm(*2) When reducing “01” (hex) from default value, receivinglevel increases by 1.0dB.ex.)Item Default Data New Data5B 5A 5CReceiving level -23.0dBm -24.0dBm -22.0dBmNote:*: When you enter the address, please refer to the table in Note: (P.55) of ENGINEERING MODE.ex.)Items (*4) Address Default Data New Data Possible AdjustedValue MAX (hex)Possible AdjustedValue MIN (hex)RemarksSending level 0F 35 Adjusted value Given value 30 00 (*1)Receiving level 0F 37 Adjusted value Given value 70 40 (*2)Battery Low 0F 04 9A - - -(*3)Frequency 00 00~00 01 00 60 - - -ID 00 30~00 34 Given value - - -(*3) Use these items in a READ-ONLY mode to confirm the contents. Careless rewriting may cause serious damage to theHandset.(*4)Items DescriptionSending level Analog Front End MIC Setting for Handset ModeReceiving level Analog Front End LSR Setting for Handset ModeBattery Low ADC value for battery low detectionFrequency Setting value of FREQ_TRIM_REGID International Portable Part Equipment Identities57KX-TG1105RUS / KX-TG1105RUT / KX-TG1106RUS / KX-TG1106RUT / KX-TGA110RUS / KX-TGA110RUT