13/332.32. KEYSTONEHexadecimal 02h 4Fh 4Bh 53h 3Ah *1 *3 *5 03hCharacter O K S : *2 *4 *6■Parameters (*1,*2,*3,*4,*5,*6)60 59 58Hexadecimal 2Dh 36h 30h 2Dh 35h 39h 2Dh 35h 38hCharacter 6 0 5 9 5 858 59 60Hexadecimal 30h 35h 38h 30h 35h 39h 30h 36h 30hCharacter 0 5 8 0 5 9 0 6 0■Response (Callback)In the period when the command can be acceptedHexadecimal 02h 4Fh 4Bh 53h 3Ah *1 *3 *5 03hCharacter O K S : *2 *4 *6AcceptabilitySECURITY STANDBY(NETWORK)STANDBY(ECO)NO SIGNAL AV MUTE FREEZE× × × ○ ○ ○2.33. SHIFT HHexadecimal 02h 56h 48h 50h 3Ah *1 *3 *5 *7 03hCharacter V H P : *2 *4 *6 *8■Parameters (*1,*2,*3,*4,*5,*6,*7,*8)127 126Hexadecimal 2Dh 31h 32h 37h 2Dh 31h 32h 36hCharacter 1 2 7 1 2 6126 127Hexadecimal 30h 31h 32h 36h 30h 31h 32h 37hCharacter 0 1 2 6 0 1 2 7■Response (Callback)In the period when the command can be acceptedHexadecimal 02h 56h 48h 50h 3Ah *1 *3 *5 *7 03hCharacter V H P : *2 *4 *6 *8AcceptabilitySECURITY STANDBY(NETWORK)STANDBY(ECO)NO SIGNAL AV MUTE FREEZE× × × × ○ ○■Note:- This command is acceptable only when the input is COMPUTER1 or COMPUTER2. In other cases, ER401 is returned.2.34. SHIFT VHexadecimal 02h 56h 56h 50h 3Ah *1 *3 *5 03hCharacter V V P : *2 *4 *6■Parameters (*1,*2,*3,*4,*5,*6)64 63 62Hexadecimal 2Dh 36h 34h 2Dh 36h 33h 2Dh 36h 32hCharacter 6 4 6 3 6 262 63 64Hexadecimal 30h 36h 32h 30h 36h 33h 30h 36h 34hCharacter 0 6 2 0 6 3 0 6 4■Response (Callback)In the period when the command can be acceptedHexadecimal 02h 56h 56h 50h 3Ah *1 *3 *5 03hCharacter V V P : *2 *4 *6AcceptabilitySECURITY STANDBY(NETWORK)STANDBY(ECO)NO SIGNAL AV MUTE FREEZE× × × × ○ ○■Note:- This command is acceptable only when the input is COMPUTER1 or COMPUTER2. In other cases, ER401 is returned.