17/332.43. AUTO SETUPHexadecimal 02h 4Fh 53h 53h 3Ah *1 03hCharacter O S S : *2■Parameters (*1,*2)ON1 ON2Hexadecimal 30h 31hCharacter 0 1■Response (Callback)In the period when the command can be acceptedHexadecimal 02h 4Fh 53h 53h 3Ah *1 03hCharacter O S S : *2AcceptabilitySECURITY STANDBY(NETWORK)STANDBY(ECO)NO SIGNAL AV MUTE FREEZE× × × ○ ○ ○■Note:- This command is effevtive only when the Signal Search selects “ON2”. In other cases, ER401 is returned.2.44. INPUT SEARCHHexadecimal 02h 4Fh 53h 52h 3Ah *1 03hCharacter O S R : *2■Parameters (*1,*2)OFF ON2Hexadecimal 30h 31hCharacter 0 1■Response (Callback)In the period when the command can be acceptedHexadecimal 02h 4Fh 53h 52h 3Ah *1 03hCharacter O S R : *2AcceptabilitySECURITY STANDBY(NETWORK)STANDBY(ECO)NO SIGNAL AV MUTE FREEZE× × × ○ ○ ○2.45. BACKGROUNDHexadecimal 02h 4Fh 42h 43h 3Ah *1 03hCharacter O B C : *2■Parameters (*1,*2)BLUE BLACK USERHexadecimal 30h 31h 32hCharacter 0 1 2■Response (Callback)In the period when the command can be acceptedHexadecimal 02h 4Fh 42h 43h 3Ah *1 03hCharacter O B C : *2AcceptabilitySECURITY STANDBY(NETWORK)STANDBY(ECO)NO SIGNAL AV MUTE FREEZE× × × ○ ○ ○■Note:- When the user regiterd Logo is not available, “BLUE” and “BLACK” are effective. In other cases, ER401 is returned.2.46. DIRECT ONHexadecimal 02h 4Fh 50h 59h 3Ah *1 03hCharacter O P Y : *2■Parameters (*1,*2)OFF ONHexadecimal 30h 31hCharacter 0 1■Response (Callback)In the period when the command can be acceptedHexadecimal 02h 4Fh 50h 59h 3Ah *1 03hCharacter O P Y : *2AcceptabilitySECURITY STANDBY(NETWORK)STANDBY(ECO)NO SIGNAL AV MUTE FREEZE× × × ○ ○ ○